click to visit StorageSearch.com home page
leading the way to the new storage frontier .....
image shows mouse building storage - click to see industrial SSDs article
industrial SSDs ..
hybrid DIMMs
hybrid DIMMs ..
click to read the article - Big versus Small SSD  architectures
Size in SSD architecture ..
disk writes per day in enterprise SSDs
DWPD ....
M2 SSDs
M.2 SSDs ..
image shows Megabyte's hot air balloon - click to read the article SSD power down architectures and acharacteristics
SSD power loss ..
..
industrial mSATA SSD
industrial grade mSATA SSDs
>2 million write cycles per logical block.
from Cactus Technologies
BiTMICRO Networks

Solid State Disks: Pushing the Envelope in Blade Server Design

by Jun Alejo, BiTMICRO Networks - November 2004
SSD ad - click for more info
Editor's intro:-With 10x lower power consumption than hard disk drives and
around 100x faster IOPS performance, the author makes a case for using
flash SSDs in SBCs / Blades instead of HDDs.
SSD ad - click for more info
..
Solid State Disks: Pushing the Envelope in Blade Server Design
SSD security
2.5" NVMe SSDs
DWPD - examples from the market
latency loving reasons for fading out DRAM
..
SSD ad - click for more info
..
A to Z index - StorageSearch.com

1.0" SSDs
1.8" SSDs
2.5" SSDs
3.5" SSDs

3 things could've killed flash SSD market

1976 - 2011 - SSD history
2007 - SSD timeline
2008 - SSD timeline
2009 - SSD timeline
2010 - SSD timeline
2011 - SSD timeline
2012 - SSD timeline
2013 - SSD market changes
2014 - SSD market changes
2015 - SSD market changes
2016 - SSD market changes

20K RPM HDDs - no-show

About the publisher
Adaptive R/W flash IP + DSP ECC
Acquired SSD companies
Acquired storage companies
Advertising on StorageSearch.com
After SSDs... what next?
Analysts - SSD market
Analysts - storage market
Animal Brands in the storage market
AoE storage
Architecture - network storage
Archives - storage news
Articles - SSD
Automotive market - storage technologies
Auto tiering SSDs

Backup articles - tape / D2d / optical
Backup software
Bad block management in flash SSDs
Benchmarks - SSD - can your trust them?
Best / cheapest SSD?
Big market picture of SSDs
Bookmarks from SSD leaders - series 1
Bookmarks from SSD leaders - series 2
boom-bust cycles in semiconductor memory
Branding Strategies in the SSD market

Cables for storage interfaces
CD, DVD and other optical storage drives
Chips - storage interface / processors
Chips - SSD on a chip & DOMs
Click rates - SSD banner ads
Cloud with SSDs inside
Consolidation trends in the enterprise flash market
Consumer SSDs guide
Controller chips for SSDs
Cost of SSDs - why so much?

Data integrity in flash SSDs
Data recovery (all)
Data recovery for flash SSDs?
DIMM wars in the SSD market
Disaster Recovery - develop procedures
Disk to disk backup
Disk sanitizers
Duplicators - optical (DVD etc)
Duplicators - HDD / SSD
DuraClass - strength metaphors in SSD brands
DWPD - examples from the market
.
Power, Speed and Strength in SSD brands
Does what marketers call their SSDs impact who SSD buyers will call?

This article surveys how vendors have played with awesome and mundane words to make their SSDs sound better - with examples from across the whole spectrum of the SSD market - the good, the bad and you know how this goes - because a Clint Eastward movie made 45 years ago is still better known than any SSD today.
accelerating the SSD marketer - click to read article And that's the challenge which wannabe T-Rexes in the SSD market have to meet. ...read the article
...
Fast Purge SSDs
The need for fast and secure data erase - in which vital parts of a flash SSD or its data are destroyed in seconds - has always been a requirement in military projects.
Fast Purge flash SSDs directory & articles Although many industrial SSD vendors offer products with extended "rugged" operating environment capabilities - and even notebooks SSDs come with encryption - it's the availability of fast data purge which differentiates "truly secure" SSDs which can be deployed in sensitive applications.
Blade server computing is fast transforming the server industry with a host of advantages in terms of design, functionality and total cost of ownership. By separating CPU and memory from other components such as cabling, power supply, network connectivity and cooling systems, blade servers significantly reduce massive enterprise server architectures into highly compact and dense form factor. According to market research company IDC, the blade server market is projected to represent nearly 29% of server unit shipments worldwide by the end of 2008.

Although its inherent compact design enhances scalability and ease of use for IT administrators, a blade server poses design challenges with regard to the installation of direct attached storage (DAS) devices. Since several blades already share the same power supply, cooling system and chassis, the most logical thing to do is to utilize a low-power, low-heat and compact hard disk drive. The first thing that comes into one's mind is the 2.5-inch mechanical disk drive, the same disk drives installed in notebook computers. However, for enterprise-wide applications, a better solution exists in the form of solid state disks (SSDs), in particular flash SSDs.

Flash SSDs are high-performance, rugged plug-and-play storage devices that contain no moving parts . Using flash memory chips for storage, these devices are available in the same industry-standard form factors (2.5-inch, 3.5-inch and PMC) and interfaces (Fibre Channel, SCSI, ATA/IDE) as hard disk drives, but instead use flash memory chips in lieu of rotational magnetic disks to store data. This article seeks to explain and illustrate how flash SSDs stack up against other storage devices in blade server applications.

Flash SSDs vs. DRAM SSDs

One SSD variant in the market today is the DRAM SSD. Used mostly in large, rackmount architectures, this device cannot be considered a viable alternative in blade server storage due to several design limitations. Owing to the volatile nature of DRAM memory, a DRAM SSD requires its own power supply, cooling fan and disk backup for data retention. These components eat up valuable space inside the drive chassis, limiting total storage capacity (less room for memory chips) and form factor (smallest DRAM SSD is 3.5-inch). Consider further its weight, and you'll have a recipe for disaster in embedded systems design.

Flash SSDs vs. HDDs

As mentioned earlier, the most important factor in finding the right DAS for blade servers is its impact on overall system performance and cost effectiveness. In terms of power consumption, mechanical hard disks typically devour around 500mA while flash SSDs consume a mere 50mA. The difference may seem insignificant in small enterprise apps, but for huge data farms, the cost savings become apparent. This further enhances the blade server's advantage over proprietary systems with regard to operational costs.

The reliable performance of mechanical disk drives can only be ensured if these drives operate within specified temperature ranges. As drive manufacturers introduce newer models featuring spindle speeds as high as 15,000 RPM, cooling has emerged as a major issue. In fact, some suppliers are providing a dedicated cooling fan or fan/heatsink combos for optimum high-speed drive performance. Unfortunately, the cooling systems of blade servers are shared, and there's no room for these add-ons.

Rugged Capabilities

Most blade server vendors are searching for more efficient means of cooling densely packed blades. Hewlett Packard's "dynamic smart cooling" initiative seeks to control heat by focusing cooling on areas identified as "hot spots." For its part, IBM is working on liquid-cooled heat sinks for server processors and water-cooled cabinets. However, these ideas are still under development and are not available now.

Unlike an HDD, a flash SSD generates minimal heat since it has no moving parts, and users can expect the same degree of high-level performance in a wider operating temperature range. These rugged features make flash SSD the most suitable storage platform for Level 3 NEBS-compliant servers. NEBS (Network Equipment Building System) refer to a set of standards established by Bellcore (now known as Telcordia) to determine electromagnetic compatibility, thermal robustness, fire resistance, earthquake and office vibration resistance, and transportation/handling durability of telecom equipment. Telecom carriers deploy equipment to remote locations with unpredictable operating conditions, and NEBS allows them to identify equipment that can provide a high degree of reliability and safety to their network.

The E-Disk Advantage

BiTMICRO Networks, a leading player in the flash SSD arena, successfully penetrated the military/industrial markets with its ruggedized E-Disk brand of flash SSDs. These models are guaranteed to operate in extreme temperatures, from -60°C to +95°C. Other environmental specs are likewise impressive, up to 150Gs of operating vibration and up to 1,000Gs of operating shock, making enterprise and carrier class applications a breeze.

One variant is the E-Disk PCI Mezzanine Card (PMC)-based plug-in flash SSD module. Suitable for blade servers (with PMC slot) that require a reliable, direct attached storage device, it features horizontal connectors that allow parallel fit onto a blade, giving plug-and-play advantages to system administrators. The E-Disk PMC can also be used as a boot and/or storage device for carrier boards such as CompactPCI, VME and MultiBus, and almost any other type of single board computer.

In the enterprise arena, the rising deployment of business intelligence, OLTP, decision support systems and other transaction-intensive applications place a premium on rapid information transfer, access and retrieval. Fibre Channel and Ultra Wide SCSI E-Disk solid-state drives' impressive performance up to 70 MB/s sustained reads, 48 MB/s sustained writes and 12,500 IOPS make them ideal for applications that exhibit grueling, rapid-fire data access brought forth in transactional and high storage bandwidth environments.

Conclusion

At present, blade servers utilize DAS mainly for system boot and application storage, with a Fibre Channel interface designed into the server to allow for a separate SAN connection. Flash SSDs can help improve, not impede, system performance with faster access times, high I/O rates and solid-state durability. Consider other factors such as hot swappability and ease of deployment, flash SSD is certainly an ideal DAS solution for blade servers. ...BiTMICRO Networks profile


SSD ad - click for more infoLater notes by editor

The advantages of placing SSD architecture in servers are now well understood and a much wider range of form factors and latencies are now feasible for blade servers.

In particular:-


more SSD articles on related themes

Introducing the 1" SSD Market
Imprinting the brain of the SSD
Increasing Flash SSD Reliability
Hard way ahead for hard drives?
Why I Tire of "Tier Zero Storage"
Data Recovery from Flash SSDs?
RAM Cache Ratios in flash SSDs
Why Seagate will Fail the SSD Challenge
a new way of looking at Enterprise SSDs
Are MLC SSDs Safe in Enterprise Apps?
the Problem with Write IOPS - in flash SSDs
SSD Myths and Legends - "write endurance"
Data Integrity Challenges in flash SSD Design
why the notebook SSD crystal ball is still murky
Market Trends in the Rackmount SSD Market
the future of enterprise data storage (circa 2020)
RAM SSDs versus Flash SSDs - which is Best?
principles of bad block management in flash SSDs
Flash Memory vs. Hard Disks - Which Will Win?
How Bad is - Choosing the Wrong SSD Supplier?
Clarifying SSD Pricing - where does all the money go?
power management architectures and characteristics inside SSDs
Calling for an End to Unrealistic SSD vs HDD IOPS Comparisons

storage search banner

STORAGEsearch is published by ACSL